Types of warehouses: classification, purpose and features

CONTENTS
Types of warehouses: classification, purpose and features

Modern warehouse categories are complex functional units that play a key role in logistics chains. When understanding warehouse types, it's important to understand that they differ in many ways, from design features to storage conditions. In this article, we'll explore the different types of warehouses, their types, and the classifications used in international practice.

Who uses warehouse storage?

The need for such premises for storing inventory arises among enterprises in various fields of activity.

Manufacturing companies need space for raw materials and finished products. Retail chains establish distribution centers to organize their product ranges. Logistics operators create transshipment terminals. Even agricultural enterprises require specialized storage facilities for their products.

Warehouse complexes are particularly important in international trade, where they act as a link between producers and consumers. Modern warehouses have become technological hubs equipped with sophisticated accounting and management systems. Their functionality has long since expanded beyond simply storing goods—today, they serve as cross-docking, picking, and pre-sale preparation centers.

Types of warehouses

Warehouse types

By appointment

Production areas . They perform a vital function in ensuring the continuity of technological processes. Raw materials, intermediate products, assembly components, and process equipment are stored in these areas, ensuring the stable operation of conveyors and production lines without downtime.

Transit terminals serve as intermediate points in the supply chain, where cargo modes or routes change. They are equipped with areas for temporary storage of goods during their transfer between vehicles.

Customs centers . These contain international cargo undergoing state control procedures. At these centers, goods remain under customs supervision until all necessary formalities are completed, after which they are transported to their final recipients in the domestic or international market.

Wholesale distribution centers . These centers handle large quantities of goods shipped to retail chains or other wholesale customers. They are strategically located near transportation hubs, reducing delivery times.

Retail distribution centers serve retail outlets, ensuring a constant supply of merchandise on store shelves. They also handle pre-sale preparation and packaging of products before they reach retailers.

Strategic reserve storage facilities . Designed to maintain safety stockpiles in case of unforeseen circumstances, they are activated in the event of force majeure, supply disruptions, or a sharp increase in consumer demand.

By product category

Storage warehouses are used to temporarily store resources, process components, parts, and consumables before they are introduced into the production cycle.

Distribution hubs serve as intermediate logistics hubs where products are stored before final shipment to retailers or direct customers.

Cold storage facilities create conditions for food products requiring strict temperature control. They are suitable for storing meat and dairy products, as well as fresh fruits and vegetables.

Specialized chemical storage facilities . Designed for the safe storage of reagents, flammable, and explosive substances.

By design

The size of warehouse facilities depends on the needs of the business. Small retail outlets can operate effectively with space of around 100 square meters, while logistics facilities in port areas often occupy areas measuring hundreds of thousands of square meters. This wide range of parameters is due to the specific nature of the turnover and the specific operating conditions of the businesses.

Types of warehouses and their classification by design:

Open storage . Enclosed or unenclosed areas designed to store products resistant to precipitation and temperature fluctuations. Construction materials, timber, and certain agricultural products are most often stored here.

Closed . Provides complete protection of the contents from the external environment. The storage facilities are equipped with ventilation, creating controlled conditions for environmentally sensitive goods such as food products, pharmaceuticals, and electronics. Modern climate control systems maintain preset temperature and humidity parameters.

Semi-open . A distinctive feature is a protected front with an open rear. This provides natural ventilation and lighting while protecting goods from direct exposure to precipitation. Ideal for products requiring moderate protection, such as packaged building materials and containerized goods.

Classification

Warehouse classification

Class "A+"

The warehouse facilities are single-level, rectangular structures. Each facility is equipped with autonomous utility systems, including an independent boiler room for temperature control, its own transformer substation, a complete HVAC system (ventilation and air conditioning), fiber-optic communication lines, as well as fire protection and utility security systems.

Design parameters

The storage space is designed with an open floor plan, with a minimum distance between supports of 12 meters or no columns at all. The minimum span width is 24 meters. The ceiling is at least 13 meters high. The floor is raised 1.2 meters above ground level and is made of high-strength concrete with an anti-dust treatment, designed to withstand a minimum load of 7 tons per square meter.

The loading area is equipped with automated gates with dock levelers, fitted with guides for precise vehicle positioning.

Requirements for the territory

The site must have a perimeter fence with 24-hour security and lighting. The development area must not exceed 45% of the total land area. The following is provided:

  • Space for maneuvering trucks
  • Two independent entrances/exits
  • Fire lanes with a width of 6 meters and more with a circular traffic organization
  • Parking pockets for trucks and cars

The complex includes administrative units, restrooms, utility rooms, server rooms, locker rooms, and staff break areas. Management is carried out through a centralized BMS platform.

Class "A"

High-quality, modern complexes with ceilings starting at 10 meters. They are equipped with burglar-proof systems and automatic gates. Dust-resistant floors can withstand heavy traffic. The space is organized for efficient use.

Fire suppression systems meet the latest requirements. Freight elevators and dock levelers expedite loading operations. Telecommunications infrastructure supports modern accounting systems. The location is conveniently located for transportation.

Class "B"

Storage facilities can be either new construction or renovated buildings, single- or multi-story. Technical equipment includes utility systems: supply and exhaust ventilation, heating circuits, fire protection systems (alarms and extinguishers), and fiber-optic telecommunications networks.

Design features

Technical specifications:

  • The minimum ceiling height is 6 meters from the floor level.
  • Concrete base with carefully leveled surface
  • The load-bearing capacity of the floor is from 4 tons per square meter.
  • Loading units are equipped with platforms and transport ramps

Organization of the territory

The land plot must meet the following criteria:

  • Full perimeter fencing with 24-hour security
  • The maximum development coefficient is 60% of the total area
  • Mandatory presence of parking zones on the territory of the complex

Additional infrastructure

The premises include:

  • Administrative and amenity block (offices, bathrooms, changing rooms)
  • Auxiliary and technical rooms
  • Freight elevators (for multi-level structures)

This class of premises has become the most widespread due to the combination of functional characteristics and financial accessibility.

Class "B+"

The main difference between Classes "B" and "B+" lies in additional infrastructure and security requirements. Class "B+" warehouses are required to have a video surveillance system, automated, remote-controlled gates, and convenient transportation access—preferably located near key highways to optimize logistics.

A key feature of such facilities is their origin. In most cases, "B" and "B+" warehouses are modernized industrial or production buildings that have undergone renovation.

Class "C"

Category "C" warehouses are permanent structures or insulated hangars equipped with basic utility systems. These facilities must be equipped with:

Heating

  • Telecommunication networks
  • Fire alarm and fire extinguishing system

Converted agricultural or industrial buildings, such as warehouses, garages, and hangars, often fall into this category. Their dimensions depend on the volume of goods stored. To improve their appearance, the facades are clad with materials that harmonize with other buildings on the site.

Design requirements

  • Ceiling height - from 4 meters
  • Floor covering - asphalt, concrete screed or tiles
  • Loading area - a ramp for convenient vehicle access

Requirements for the territory

  • Fenced perimeter with access control

Additional terms and conditions

  • Administrative premises for staff
  • Utility and technical areas
  • Freight elevator or lift (if the warehouse has multiple floors)
  • Ground level gates for easy loading/unloading

Important: If an object does not meet at least one of the listed criteria, it may be considered as a lower class “D”.

Pneumatic hangar

Pneumatic hangars (pneumatic hangars) are quickly erected structures that are widely used in various fields, from aviation to industrial storage.

Where are pneumatic hangars used?

  1. Aviation and airfields

    • Temporary storage of aircraft and helicopters
    • Protecting aircraft from precipitation, ultraviolet radiation, and temperature fluctuations
    • Mobile hangars for expeditionary and military needs
  2. Industry, logistics

    • Warehouses for raw materials and finished products
    • Shelters for construction and agricultural equipment
    • Temporary production sites
  3. Sports and events

    • Indoor training areas
    • Exhibition pavilions, concert venues

Advantages of pneumatic hangars:

  • Quick installation. Installation takes anywhere from a few hours to a few days.
  • Mobility. The structure can be disassembled and transported to a new location.
  • No internal supports. Free space for large equipment.
  • Budget savings. Cost is lower than that of permanent hangars.
  • Reliable materials. Reinforced PVC membranes with UV and weather protection.

Technical capabilities:

  • Span width up to 100 m
  • Possibility of equipping with heating, ventilation, lighting
  • Automatic pressure maintenance system

Class "D"

Basements, garages, hangars, and other temporary storage solutions lack climate control systems and often fail to meet safety standards. They are used for short-term storage of low-maintenance goods.

Limited space and low ceilings make it difficult to organize the space efficiently. Access roads can be difficult. Utilities are limited to the bare minimum. These are used when budgets are tight.

Conclusion

Selecting warehouse space for a business requires a thorough analysis of the client's needs. Modern classification systems help navigate the diverse offerings. From simple hangars to high-tech terminals, each solution offers its own advantages for specific tasks. A well-chosen warehouse becomes a significant competitive advantage in the supply chain.

HANGAR MAKER specializes in the design and construction of turnkey inflatable hangars. We offer:

  • Custom solutions – hangars of any size (up to 100 m wide) taking into account the climatic features of the region.
  • Durable materials – use of reinforced PVC membranes that are resistant to UV radiation, wind and precipitation.
  • A complete set of engineering systems – ventilation, heating, lighting, automatic pressure maintenance.
  • Installation, maintenance – assistance with installation and subsequent support of the facility.
  • Inflatable hangars are the optimal combination of price, construction speed, and functionality.

If you need reliable shelter for airplanes, helicopters, or other cargo, HANGAR MAKER can handle projects of any complexity.


Fast installation
(12 to 72 hours)
No capital
foundation required
High mobility
and easy relocation
Easy dismantling
and relocation
Need a consultation?
Our manager will contact you to clarify all details.
Sending...
Previous article

Do you need a prefabricated structure?
Consult us!

×